The Resideo Honeywell Home PROSiXFLOOD is a wireless flood sensor with external probe (FP280) that is intended for use with control panels that support PROSiX-Series devices. The PROSiXFLOOD detector is compatible with the ProSeries PROA7, ProSeries PROA7C, ProSeries Canada PROA7CN, ProSeries PROA7PLUS, ProSeries PROA7PLUSC or ProSeries Canada PROA7PLUSCN all-in-one wireless touchscreen control panels. When the PROSiXFLOOD sensor's probe contacts water, the sensor sends an alarm or trouble signal to the controller depending on zone type selected (ex. trouble = Monitor Zone; alarm = 24hr Aux) within 15 seconds (depending on the alarm delay). The flood sensor is supervised for an open circuit (cut wire) and sends a trouble signal up to 15 seconds after the condition is sensed. The PROSiXFLOOD also has a front cover tamper and wall tamper switch.
To mount the sensor, open the device and firmly slide the front and back housings in opposite directions to pull them apart. Mount the PROSiXFLOOD to a wall, using the double sided tape and screws provided. Connect the flood probe's wires to the PROSiXFLOOD terminals. Mount the flood probe in the area where flood notification is desired. Secure probe with #6 x 3/4" pan head screw provided. Lastly, reattach front cover and secure with #2 x 1/4" screw provided.
To enroll set the PROSiX-Series panel in programming mode and when prompted pull the battery tab to activate the PROSiXFLOOD (Use the tamper switch if the battery tab is removed). The LED flashes (up to 20 seconds) during enrollment. When done, the LED is ON for 3 seconds and the control beeps to confirm enrollment. If the device is not successfully enrolled during the enrollment period, the LED turns off and the device powers down. Activate the tamper switch to restart the enrollment process. After enrolling and before mounting, verify adequate signal strength by conducting a sensor test with the device in its intended mounting location. Adjust the device location and orientation as necessary.
If the device is enrolled in a panel different than the intended panel (within the 24-hour enrollment deletion and default), and you are unable to delete it from the unintended panel, reset the device to factory default setting. Once the PROSiXFLOOD is enrolled in a system, after 24-hours enrollment timeframe, the sensor cannot be used with another controller until it is removed from the current controller.
After enrollment, the PROSiXFLOOD can be tested by placing the probe in a cup of water. The control panel should indicated a fault condition.